Data logger/storage

econ unit+ V2 & accessories

Product profile and data sheet

Your advantages at a glance

  • Multi-talent for energy and consumption metering
  • Configuration via platform-independent web browser
  • Plug & Play integration into the econ4 energy management software
  • Connection of a wide range of sensors and measuring devices
  • Several interfaces to choose from (M-Bus / BACnet / Modbus)
  • Optionally also available as WIFI version

Your advantages at a glance

  • Multi-talent for energy and consumption metering
  • Configuration via platform-independent web browser
  • Plug & Play integration into the econ4 energy management software
  • Connection of a wide range of sensors and measuring devices
  • Several interfaces to choose from (M-Bus / BACnet / Modbus)
  • Optionally also available as WIFI version
econ unit+ V2 Schema

econ unit+ V2 - Data logger of the latest generation

The econ unit+ V2 is a powerful data logger for recording energy and consumption in buildings, on machines and systems. The recorded data is processed in the econ4 energy management software.

Just like our other hardware components, the data loggers are plug & play. This means that they integrate directly into your existing infrastructure. Nevertheless, the system remains scalable and is easy to expand.

 

Versions, extension modules and accessories

econ unit+ V2 Standard / econ unit+ V2 with WIFI interface
Datenlogger: econ unit V3 und econ unit V3 WLAN

Powerful data logger for recording energy and consumption in buildings, machines and systems.

  • Configuration via platform-independent web browser
  • Plug & Play integration into the econ4 energy management software 
  • Compact housing for installation on a top-hat rail
  • Two Ethernet ports with daisy chain function for linking additional devices, e.g. econ sens3
  • M-Bus and Modbus RTU interface allows different meters to be read, e.g.electricity, water, gas and heat (up to 80 M-Bus loads / up to 32 Modbus RTU participants)
  • Can be integrated into a BACnet/IP or Modbus TCP network (Modbus server)
  • Connection of expansion modules (simple, quick wiring with jumper plug)
  • Measured values can be sent (push) from the database via email (SSL) and FTP (SFTP)or read out (pull) via FTP (SFTP) either alternatively or in parallel
  • Digital inputs (8x inputs for recording and counting binary states up to 24 V DC, including 4x contact inputs for potential-free switches, also suitable for counting S0 pulses)
  • Digital outputs (4x transistor outputs with current limitation)
  • Relay outputs (4x changeover contacts)
  • Analog inputs (3x configurable for resistance, voltage and current measurement) and analog outputs (3x)
  • Operating voltage 24 V DC +/- 10 % (external power supply required)
  • Optional WLAN interface for connection to a WLAN network (operating modes: infrastructure and ad-hoc)

Article no.:EC250888 (econ unit+ V2 Standard) /EC251016 (econ unit+ V2 with WLANinterface)

Power supply econ unit+ V2
econ_NG4_Netzteil

An external power supply is required to operate the data logger.

  • Regulated direct voltage of 24 V DC +/-10% /16W
  • Can be connected in series via jumper plug 
  • Suitable for econ unit+ V2, econ unit+ V2 WLAN and econ unit+

Article no.: EC229025

IR readout adapter with M-Bus connection
econ-IR-Ausleseadapter

Adapter for the data logger for reading electricity or gas meters via optical interface. The data is transmitted via M-Bus.

  • The readout adapter is attached to the optical interface (DIN EN 62056-21) of the energy meter 
  • A neodymium permanent magnet provides the necessary holding force
  • Cable length 1,20 m
  • Suitable for econ unit+ V2 and econ unit+ V2 WLAN

Article no.:EC251025

Extension module 4xanalog to Modbus RTU
Erweiterungsmodul 4xAnalog zu Modbus RTU

Module with 4 analog inputs for recording currents and voltages, e.g. from active temperature sensors, electric ventilation and mixing dampers, valve controls, etc. Each input can be set as either a current or voltage input using a DIP switch on the front panel. With a Modbus master such as the econ unit+ V2, the inputs can be queried via standard registers. Suitable for decentralized mounting on TH35 mounting rail in electrical distribution boards.

Can be used for unit+ V2 / unit+ V2 WIFI. The connection between the devices is made via jumper plug (included in the scope of delivery).

Item no. EC251098

Extension module 4xS0 to Modbus RTU
Erweiterungsmodul 4xS0 zu Modbus RTU

Module with 4 S0 inputs for counting S0 counter pulses. In the event of a power failure, the last counter readings are saved. The inputs can be queried via standard registers using a Modbus master such as the econ unit+ V2. Suitable for decentralized mounting on TH35 mounting rail in electrical distribution boards.

Can be used for unit+ V2 / unit+ V2 WIFI. The connection between the devices is made via jumper plug (included in the scope of delivery).

Article no.: EC251063

Extension module for recording pulses
Erweiterungsmodul S0_M-Bus Converter

With Module S0/M-BusConverter the data logger is extended by 4 pulse channels.

  • 4-channel pulse counter for counting of pulses generated by energy meters via reed contacts or passive transistor outputs (open collector) in relation to the measured energy
  • Suitable for econ unit+V2 and econ unit+ V2 WIFI

Article no.: EC231817

WIFI antenna with magnetic base
WLAN-Antenne mit Magnetfuß

Optional antenna plus cable for the data logger (EWIO2-M) and Ethernet I/O (EWIO2) with WIFI connection.

  • Antenna with magnetic base
  • SMA connector
  • Cable length: 1 m

Item no. EC251139